<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-24 15-01-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.40 MHz 4/5, 49 dBuV RIRE &
Pilot RDS Phase Difference
7.1 kHz 4.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
12 kHz 74 kHz 7953 15,4533
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
5,3 dBr 6,44 dBr 7,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RIRE & " F226 0 (No PTY) 1 0 1 2 15:01, 24.02.2025
RT
"RIRE & CHANSONS "
AF EON
91.4, 92.0, 92.1, 94.4, 95.4, 96.2, 97.3, 97.4, 97.5, 97.6, 103.3, 104.4, 107.3 MHz -
FM Scope Station: 97.40 MHz, signal: 4/5 (48 dBuV) Max at: 74 kHz MIN: 12 kHz % above 75 kHz: 15,4533 Acquired: 2025/02/24 15:00:43 Total samples: 7953 Equivalent time: 0:06:37 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 7,7 dBr MIN: 5,3 dBr AVE: 6,44 dBr % above 10,0 dBr: 0,0 Last value: 6,3 dBr (2025/02/24 15:00:42) Station: 97.40 MHz, signal: 4/5 (48 dBuV) 14:54 14:55 14:56 14:57 14:58 14:59 15:00 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality